Skip to content

Automatic translation — the Portuguese version is the reference. View in Portuguese

Updated on 2026-10-04

Central Bank (SGS) — connector

Reads a public time series from the Central Bank's Time Series Management System (Selic, IPCA, PTAX, CDI…) for a period and loads it into the Bronze layer.

On this page (15)

Read first: ../conectores.md (state map) and fichas.md (index of the datasheets).


What it is#

Reads a public time series from the Central Bank's Time Series Management System (Selic, IPCA, PTAX, CDI…) for a given period and loads it into the Bronze layer.

Supported ingestion modes:

  • Nós buscamos — We fetch the data from your source.

What it's for#

Bring Banco Central (SGS) data into your datalake and make it available to the Bronze/Silver/Gold layers, BI models, and the natural language question wizard.

When to use / when not to use#

Use when you need to consolidate this source into the datalake on a scheduled basis, with isolation per workspace.

Remember that the first run with a real credential is followed by our team before the connector is fully released.

Plan and permissions#

  • Plan: core product (connectors are included in all plans; the limit is the number of sources in the plan).
  • Access: requires an active workspace — with subscription overdue, suspended or canceled, the run is blocked.
  • Shutdown: ingestion runs can be temporarily turned off (maintenance or incident). When this happens, the UI indicates the resource is unavailable at the moment.

Prerequisites#

  • No credential required: the data is public.
  • The Central Bank's open data API is public. Provide the series code in SGS (e.g., 11 daily Selic, 433 monthly IPCA, 1 PTAX sell dollar) and the period in dd/MM/yyyy. Note: for daily series the Central Bank limits each query to 10 years — split larger periods into more than one source.

Credentials#

Authentication method: No credential — public data.

This connector does not require its own secrets (upload mode / no credential on the platform).

Secrets are never re-displayed and undergo redaction in all errors/logs (raw token, URL-encoded and in JSON).

Form fields#

FieldLabelTypeRequiredNote
serieSérie code (SGS)textyesdefault: 11; Series number in the SGS catalog. Ex.: 11 (daily Selic), 433 (monthly IPCA), 1 (PTAX sell dollar), 4389 (annualized CDI).
dataInicialStart datetextyesFormat dd/MM/yyyy. Daily series: maximum 10 years up to the end date.
dataFinalEnd datetextyesFormat dd/MM/yyyy. Can be a future date — the Central Bank returns up to the last published value.

Step by step#

  1. In the menu Dados → Conexões, use Nova conexão.
  2. Choose Banco Central (SGS) in the catalog.
  3. Fill in the form fields (see the table above).
  4. Use Testar conexão. The result is shown broken down into Conectividade, Autenticação and Listagem/leitura — each with OK, Failed, Not applicable or Not tested. A capability with no test of its own for this connector shows as Not applicable, and Not applicable never counts as success.
  5. Use Salvar conexão. Saving does NOT start any ingestion.
  6. On the connection card, use Montar extração (or go to Orquestração → Pipelines and use Conectar fonte). The pipeline points to the saved connection — the credential is not copied.
  7. In the review, Publicar (agenda desligada) creates version 1 without executing anything. Then, Ativar agenda and Executar agora are separate actions.

Example — connection test#

Sample configuration (all values are fictitious; secrets appear masked):

text
# Exemplo sintético (valores fictícios — não são credenciais reais)
serie = 11
dataInicial = <dataInicial>
dataFinal = <dataFinal>

Expected result#

The Testar conexão returns the list of discovered tables/resources. After the first load, rows appear in the Bronze layer of your workspace, ready for the pipeline.

Limits and costs#

  • Pagination: hard ceiling per run (default 10,000 pages / 5,000,000 rows); anti-loop guard.
  • SaaS load: default batchSize 5,000, maxRows 200,000 per resource.
  • Estimated volume: ~0.01 GB/month (catalog estimate, not measurement).
  • Cost: the extraction itself is not billed by the platform; the Bronze load consumes datalake processing (billable).

Security#

  • Scope by workspace: each client reads and writes only in their own datalake (<prefix>_bronze / _silver / _gold); there is never leakage between workspaces.
  • Encrypted secrets: sensitive material is encrypted with AES-256-GCM before being stored. The external credential vault is optional and linked per connection; without it, the encrypted value is stored in the database. Changing the value here does NOT revoke the credential at the origin.
  • Redaction: all errors/logs go through secret redaction (raw, URL-encoded and in JSON).
  • Production doesn't fake: a path that would fall into a mock triggers the production guard (explicit failure instead of simulating success).

Common errors#

  • Credential rejected (401/403) — the provider did not accept the credential: expired, revoked or lacking necessary permission. Reconnect the source (the source and history are preserved; do not recreate the source).
  • Rate limit (429) — the provider asked to wait. The extraction respects Retry-After and retries; if repeated, wait and reduce the schedule frequency.
  • Resource not found — check the resource identifier (account, object, report) and the granted permissions.
  • Pagination cursor stuck — the extraction stops when the API cursor does not advance (anti-loop guard). If it happens in successive runs, open a support ticket indicating the connector and the resource.
  • Empty records path — the response arrived without records in the expected place. Check the selected resource and filters (period, account, status) before assuming there is no data.

Troubleshooting#

  • Use Testar conexão to isolate credential/network issues before scheduling.
  • Monitor runs in the connector observability (error rate, p50/p95, freshness).
  • A schema change at the origin is flagged by the schema drift (new column = info; removed column/type changed = attention).

Related#


Last review: 2026-10-04. Datasheet automatically generated from the product's connector catalog.

Related links